CHOSUN

鹽害損傷된 鐵筋콘크리트構造物의 下部大斷面 補强에 관한 硏究

Metadata Downloads
Author(s)
박종환
Issued Date
2006
Abstract
This paper deals with the strengthening method for the Increase durability of the reinforced concrete structures with Chloride Damage, and the purpose of this research is to develop the construction method and materials for extending the lower large section of the structures which is set up on the sea. Accordingly, a reinforced concrete pier, which has serious damage at the lower large section, is adopted as the subject structure for the study.
A close safety inspection is taken on this structure and the utilizing condition and the structural capacity should be taken into consideration, it needs mending, reinforcement and limitation of using. Besides, it also needs its lower large section to be extended so that it can resist the increased load up to about 30% heavier than one of existing design.
The choice of an method of repairing or extending the lower large section for the structural reinforcement like the matter in this study, the following components are necessary. They include weather condition of the ocean surroundings, environmental pollution, and the limit of working time by the difference of the ebb and the flowing of the tide. They also contain the solution of the problems of concrete structures forward the opposite direction 300~500mm from the lower to the upper, Repeating the work by intervals several times can get more or less thick.
In addition, by preventing cold joint from working among layers, the wet jet spray method which unifies the concrete structures and increases the utilizing and durability of the concrete structures, is chosen.
In this study, the mock-up tests on a model structure, which is a similar structure, are executed according to the repairing and strengthening method which are applicable to extending the lower large section of the reinforced concrete structure set up on the sea, and the application and problems are examined. As a result of the Mock-up tests, the wet spray method is suggested to be the most suitable for the extending the lower large section of the reinforced concrete pier.
The lower large section extension work of the subject is executed with the newly-developed material and the method for strengthening, and as a result of the quality inspection, the material and method prove their superiority since the compression and adhesion strength of the concrete are huge, and the adhesion between the glass fiber and the section extended is great. In conclusion, the wet jet spray method increases the safety rate of bending enormously. the durability and the utilizing of cracking width are found very satisfactory because cracking width in all the section decreases rapidly below the permitted cracking width.
As the material and the strengthening method developed in this study bring about little possibilities of polluting the ocean, make it easy to operate on the sea, and have great adhesion not only between the existing and new concrete but also among each mortar layers, they are considered to be very suit to strengthening and extension of the reinforced concrete structure set up on the sea.
Alternative Title
A Study on Strengthening for Lower Large Section of the Reinforced Concrete Structures with Chloride Damage
Alternative Author(s)
Park, Joung Hwan
Affiliation
조선대학교 대학원
Department
일반대학원 토목공학과
Advisor
朴吉鉉
Awarded Date
2007-02
Table Of Contents
표목차 = iv
그림목차 = vi
사진목차 = viii
ABSTRACT = ix
제 1 장 서론 = 1
1.1 연구목적 = 1
1.2 연구동향 = 4
1.3 연구내용 및 방법 = 7
제 2 장 철근콘크리트구조물의 염해 메커니즘 = 10
2.1 염해환경 = 11
2.2 염화물이온의 침투경로 = 14
2.2.1 내부 염화물이온 = 14
2.2.2 외부 염화물이온 = 14
2.3 염화물이온과 철근의 부식 = 16
2.3.1 염화물이온과 부식반응 = 16
2.3.2 부식반응과정 = 19
2.4 염해의 영향인자 = 22
2.4.1 외부 영향인자 = 22
2.4.2 내부 영향인자 = 23
2.5 염해에 의한 내구성능 저하과정 = 24
2.5.1 잠복기 = 25
2.5.2 진전기 = 26
2.5.3 가속기 및 열화기 = 28
제 3 장 내구성 평가 = 30
3.1 대상구조물 = 31
3.2 시험방법 및 평가기준 = 32
3.2.1 노후화현상조사 = 32
3.2.2 균열조사 = 34
3.2.3 콘크리트강도 측정 = 35
3.2.4 철근부식도 측정 = 36
3.2.5 염화물함량 시험 = 37
3.2.6 콘크리트중성화 시험 = 38
3.3 평가결과 및 고찰 = 39
3.3.1 노후화현상 조사결과 = 39
3.3.2 균열 조사결과 = 41
3.3.3 콘크리트압축강도 측정결과 = 42
3.3.4 철근부식도 측정결과 = 46
3.3.5 염화물함량 시험결과 = 46
3.3.6 중성화 시험결과 = 47
3.4 종합평가 및 조치 = 48
3.4.1 정밀 조사결과 = 48
3.4.2 구조물 상태평가 = 49
3.4.3 내구성 증진을 위한 조치사항 = 51
제 4 장 하부대단면 보강공법 = 52
4.1 무수축모르터 그라우팅공법 = 55
4.1.1 중력식 목재거푸집공법 = 55
4.1.2 중력식 Steel Plate Jack-up공법 = 57
4.2 마운트그라우팅공법 = 59
4.2.1 무수축모르터 마운트그라우팅공법 = 60
4.2.2 무수축모르터 마운트그라우팅 Jack-up공법 = 62
4.3 Micro-silica 건식 Jet스프레이공법 = 65
4.3.1 공법의 특징 = 66
4.3.2 시공순서 = 67
4.3.3 Mock-up Test = 69
4.3.4 공법적용 가능성검토 = 72
4.4 습식 Jet스프레이공법 = 73
4.4.1 공법의 특징 = 75
4.4.2 시공순서 = 79
4.4.3 Mock-up Test = 81
4.4.4 공법적용 가능성검토 = 93
4.5 습식 Jet스프레이공법의 적용 = 94
4.5.1 습식 Jet스프레이공법 = 94
4.5.2 품질검사 = 96
제 5 장 보강단면에 대한 내구성 및 사용성 평가 = 102
5.1 구조해석조건 = 103
5.1.1 해석모델 = 103
5.1.2 단면조건 = 105
5.1.3 재료조건 = 107
5.1.4 하중조건 = 107
5.2 구조해석 = 110
5.3 내구성 평가 = 113
5.4 사용성 평가 = 118
5.5 평가결과 = 122
제 6 장 결론 = 123
참고문헌 = 125
부록 A 보강공사 공정 = 130
부록 B 품질검사 장면 = 133
Degree
Doctor
Publisher
조선대학교 대학원
Citation
박종환. (2006). 鹽害損傷된 鐵筋콘크리트構造物의 下部大斷面 補强에 관한 硏究.
Type
Dissertation
URI
https://oak.chosun.ac.kr/handle/2020.oak/6668
http://chosun.dcollection.net/common/orgView/200000234099
Appears in Collections:
General Graduate School > 4. Theses(Ph.D)
Authorize & License
  • AuthorizeOpen
  • Embargo2008-09-10
Files in This Item:

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.