In this study, A seismic strengthening system using multi steel tube unit was developed. This system applied the stiffness and strength enhancement method, which is an effective seismic reinforcement technique for the existing non-seismic buildings of middle and low-rise buildings. It was intended to compensate for the shortcomings of the existing seismic strengthening systems. It is designed to improve constructability through factory production and to allow for variability.
In order to adopt an effective layout and bonding method with the existing structure, multi steel tube unit experiments were conducted. It was divided into two classifications according to the layout and two classifications according to the bonding method with the existing structure. As a result, the joining method using a square steel tube was more effective than the joining method using an steel plate at the point of lowering rigidity or maximum bearing capacity. In the joint method using steel plates, force transmission to the seismic reinforcement system was not performed well due to the destruction and separation of the welds at the corners.
In order to verify whether effective seismic design and seismic strengthening are possible, a quasi-dynamic experiment was conducted on a specimen with non-seismic details of a two-story scale reinforced with a multi steel tube unit seismic strengthening system. After that, the results were compared through structural analysis. As a result, the specimen strengthened with the multi steel tube unit seismic strengthening system improved the stiffness and shear strength by 2.1-4.4 times and 2.1-2.8 times, respectively, compared to the specimen with non-seismic details. In addition, it was confirmed that the analysis results were more conservative than the experimental results. Therefore, it is judged that effective seismic design and seismic strengthening by applying the multi steel tube unit seismic strengthening system is possible.
The purpose of this study was to prove the effective reinforcing effect of the seismic strengthening system for multi steel tube unit. Therefore, seismic performance evaluation was performed through a nonlinear static analysis of a frame model with a scale of five stories above the ground. As a result, the initial stiffness, strength, and ductility of the strengthened model were all increased, and the load resistance performance was improved.In addition, the effective reinforcement effect was demonstrated in accordance with the seismic performance standards.
Alternative Title
A Study on the Seismic Strengthening System Using Multi Steel Tube Unit
Alternative Author(s)
LEE SUNJU
Affiliation
조선대학교 일반대학원
Department
일반대학원 건축공학과
Advisor
조창근
Awarded Date
2022-02
Table Of Contents
제1장 서론 1
제1절 연구 배경 및 목적 1
제2절 연구 동향 2
제3절 연구내용 및 방법 6

제2장 다중 각형 강재 유니트 내진보강시스템 8
제1절 다중 각형 강재 유니트 내진보강시스템 개요 8

제3장 다중 각형 강재 유니트 실험 11
제1절 실험체 개요 11
1. 개요 11
2. 재료 11
3. 실험 변수 및 실험체 제작 11
4. 가력 상세 및 측정 방법 16
제2절 실험 결과 19
1. 하중 변위 곡선 19
2. 파괴양상 25
3. 강성 및 전단력 33
제3절 소결 36

제4장 2층 다중 각형 강재 유니트 보강골조 실험 및 구조해석 37
제1절 실험체 개요 37
1. 개요 37
2. 재료 38
3. 실험 변수 및 실험체 제작 42
4. 가력 상세 및 측정 방법 55
제2절 실험 결과 59
1. 하중 변위 곡선 59
2. 균열진전 및 파괴양상 65
3. 강성 및 전단력 87
제3절 해석 결과와 실험 결과 비교 및 평가 90
제4절 소결 95

제5장 다중 각형 강재 유니트 보강골조 성능평가 97
제1절 대상 건축물 계획 97
제2절 비선형 정적해석 통한 내진성능평가 101
1. 성능 곡선 및 성능점 101
2. 밑면전단력 105
3. 소성힌지분포 107
4. 층간변위비 및 최대변위 112
제3절 소결 116

제6장 결론 118

참고문헌 120
Degree
Master
Publisher
조선대학교 대학원
Citation
이선주. (2022). 다중 각형 강재 유니트 내진보강시스템에 대한 연구.
Type
Dissertation
URI
https://oak.chosun.ac.kr/handle/2020.oak/17278
http://chosun.dcollection.net/common/orgView/200000590469
Appears in Collections:
General Graduate School > 3. Theses(Master)
Authorize & License
  • AuthorizeOpen
  • Embargo2022-02-25
Files in This Item:

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.