CHOSUN

EU Stress Test와 국내 원전 안전점검 결과의 비교를 통한 안전성 개선 항목의 적절성 평가

Metadata Downloads
Author(s)
강화성
Issued Date
2016
Keyword
안전점검, 스트레스테스트
Abstract
ABSTRACT
AdequacyEvaluation ofSafety ImprovementItems by Comparing the Results ofDomestic NPP Safety Reviews and EU Stress Test

By Kang Hwa Sung
Advisor : Prof. Kim Jin Won, Ph.D.
Departmant of Nuclear Engineering,
Graduate School of Chosun University

This paper is to confirm an necessity of introduction EU stress test for domestic continued operation nuclear plant, evaluate adequacy of safety improvement items and derive additional improvement items, as comparing the performing process, check criteria and inspection results about the domestic nuclear plant safety check and Eu stress test performed After the Fukushima nuclear accident. EU stress test was more systematic process and had detailed criteria, but the inspection results(of Cernavoda NPP) is not more powerful and appropriate for enhancement safety of NPP than domestic safety check. It is focusing in prevention of accident beyond design basis, but the national safety check includes the prevention and respond. therefore, the national safety check is thought as more spacious range and excellence.
Nevertheless, the government performed again the EU stress test for the continued operation of domestic NPP, because the regulatory agencies did not give the technical confidence to the public and did not enjoy the confidence of people by applying the acceptability of public to national regulation. If this situation is persisted, the domestic nuclear power business is expected to be more difficult because of the people's distrust about nuclear safety and the regulation being strengthened in various field(safety, physical protection, cyber security. etc.).
To prepare for the difficult situation that the domestic water can not be provided to plant due to the future severe drought or earthquake, Domestic NPPs need to be reviewed to dig a deep well within site and purchase a small mobile generator truck to supply electric power to water pump of the well

Keyword : stress test, safety check, inspeciton, continued operation
Alternative Title
AdequacyEvaluation ofSafety ImprovementItems by Comparing the Results ofDomestic NPP Safety Reviews and EU Stress Test
Alternative Author(s)
KANG, HWASUNG
Affiliation
원자력공학과
Department
일반대학원 원자력공학
Advisor
김진원
Awarded Date
2016-08
Table Of Contents
목 차

ABSTRACT iv

제 1 장 서 론 1

제 2 장 후쿠시마 원전사고 후 국내 및 EU후속조치 비교 2
제 1 절 후쿠시마 원전사고 개요 2
제 2 절 국내 원전 안전점검 2
1. 안전점검 당시의 국내원전 현황 2
2. 국내 원전 안전점검 수행과정 2
3. 국내원전 안전점검 기준 3
4. 점검 결과 5

제 3 절 유럽연합(EU) Stress Test 23
1. 루마니아 체르나보다 원전 현황 23
2. EU Stress Test 수행 과정 24
3. EU Stress Test Specification(점검기준) 24
4. 루마니아 체르나보다 원전 Stress Test 국가보고서 36

제 4 절 국내원전 안전점검과 EU Stress Test 비교 75
1. 수행과정 비교 75
2. 점검기준 비교 75
3. 점검결과 비교 77

제 3 장 결론 83

참고문헌 85
Degree
Master
Publisher
조선대학교
Citation
강화성. (2016). EU Stress Test와 국내 원전 안전점검 결과의 비교를 통한 안전성 개선 항목의 적절성 평가.
Type
Dissertation
URI
https://oak.chosun.ac.kr/handle/2020.oak/12846
http://chosun.dcollection.net/common/orgView/200000265600
Appears in Collections:
General Graduate School > 3. Theses(Master)
Authorize & License
  • AuthorizeOpen
  • Embargo2016-08-25
Files in This Item:

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.