대기오염측정망 원격관리시스템 구축에 관한 연구

Metadata Downloads
Author(s)
서광엽
Issued Date
2009
Abstract
Caused by air quality sampling pump networks, results of the studies on solutions of noise and improvement of the work environment, answers in advance for implementing a remote management system , air pollution and air quality monitoring networks time of the inspection and measurement of data reliability and effective management measures for study how to manage are the following.
By attaching Large by pass In-Line Filter in the PM analyzer(R&P, TEOM 1400AB) which is ordinarily thrown away when used for 6 months to one year to sampling extracting pumps and recycling it, the degree of noise has been reduced by 16.6dB(A). In result, suggestion of fundamental solutions of noise and improvement of work environment have been made. Furthermore, with the recycle of used materials, the budget could be reduced.
With gas ventilator idea production establishments of the used gas which is measured in the measurement machinery and tools and then is thrown away, it contributed to PVC(Polyvinyl chloride) material erosion shields which are caused by with ozone where comes out from the workplace improvement and the dioxide nitrogen measurement machinery and tools. And a devide has been developed in order to check the capability of the pumps with outlet tubes.
The Teflon tube and stainless steel pipe used for connection tube between mixture standard gas tank and correction equipment and stainless steel pipe have been tested for 6 months. As a result there was no leakage in the stainless steel pipe compared to the Teflon tube. This stainless steel pipe was used as mixture standard gas tank. So it could avoid leakage of mixture standard gas pipe. Also it reduced disturbance time period of mixture standard gas tank by shortening the length of the pipe.
For the prevention from wrong function of the system which is caused by software related problems but not by hardware related problems of data logger and the minimization of a measurement data discontinuation or being washed away, data logger reset module have been developed for the environment of 100% remote connection and control.
By employing 2-way solenoid valve, it is connected to the condensate issue of compressed air and remotely controlled. The compressed air supply which contains condensate exhaust function that makes condensate water automatically discharged has been developed. Therefore, it has made it possible to create an air pollution measurement network remote system construction environment. In addition, by making the air compressor outlet connected with the 2-way solenoid valve system double, connecting 3-way solenoid valve and having assisting characteristic gas in THC analyzer, the condensate water exhaust device has been developed in order for condensate water not to flow into the meter.
Constructing a remote management system will be able to control both the measuring range of the analyzer and the power of ventilator, which brought work place environment improvement, prevention of the loss of analyzer and finally made it possible to reduce budget.
With the construction of a remote measuring instrument monitoring system, and by monitoring measurement interior environment, the efficiency of analyzer, condition of the analyzer, diagnosis of the broken and its measures and the state of measurement meters at all times, the efficiency and the condition of analyzer are checked without any business trips. After the efficiency and condition of the analyzer and tools are checked, the reliability of measurement data and capability of measurement meter are available by having repair measurement in advance and timely changing the expendable and the degradation materials.
With the Constructed remote reform systems, zero/span drift problems cause by their long time uses are solved by checking zero and span at all times. This has improved the accuracy and a reliability of measurement data.
With remote management system implementation, the case of Gwangju city , it could bring decrease for business trip time for inspection. Generally, it used to take over 30 hours, 4 times a week for inspection. However, it reduced it into once a week and only 4 hours. It also reduced \47,000,000 to \58,000,000 Won every year. Furthermore, if they are installed in 262 measurement path in 16 cities nationwide, it could be reduced \982,000,000 Won or more annually.
Alternative Title
A Study on the Implementation of Remote Management System for Air Quality Monitoring Networks
Alternative Author(s)
Seo, Gwang Yeob
Affiliation
조선대학교 일반대학원
Department
일반대학원 환경생명공학과
Advisor
신대윤
Awarded Date
2009-08
Table Of Contents
제1장 서 론 1
제1절 연구배경 1
제2절 연구목적 3

제2장 이론적 배경 4
제1절 대기오염의 영향 4
1. 대기오염의 정의 4
2. 대기오염의 인체 및 환경영향 5
가. 아황산가스(SO2) 5
나. 이산화질소(NO2) 6
다. 오존(O3) 7
라. 일산화탄소(CO) 8
마. 총탄화수소(THC) 8
바. 먼지(PM10, PM2.5) 9
사. 납(Pb) 10

제2절 대기환경기준 11
1. 환경기준의 필요성 11
2. 환경기준의 성격 11
3. 환경기준의 설정 목적 12
4. 환경기준의 설정 근거 12
5. 우리나라 대기환경기준 13

제3절 대기오염측정망 현황 및 종류 14
1. 대기오염측정망 현황 14
2. 대기오염측정망 종류 14

제4절 대기오염측정망의 측정원리 16
1. 대기환경기준 항목 측정방법 및 원리 16
가. 아황산가스(SO2) 측정기 16
나. 이산화질소(NO2) 측정기 16
다. 오존(O3) 측정기 17
라. 일산화탄소(CO) 측정기 17
마. 미세먼지(PM10) 측정기 17
2. 대기환경기준 이외 항목의 측정방법 및 원리 18
3. 항목별 측정주기 19

제5절 대기오염측정망 자료관리 20
1. 자료검색 20
2. 측정자료 관리 21
3. 유효 가동률 21
4. 대기오염 측정치 단위 및 유효 자리수 21

제6절 대기오염측정망 관리 22
1. 대기오염측정망 유지보수 위탁관리 22
2. 대기오염측정망 정도관리 24

제7절 국내 ․ 외 대기오염측정망 운영현황 38
1. 국내 38
가. 광주광역시 41
나. 전국 16개 광역자치단체 42
2. 국외 44
가. 일본, 중국 44
나. 미국 46
다. 유럽(영국, 프랑스, 독일) 51

제3장 연구내용 및 방법 53
제1절 연구내용 53
제2절 연구방법 56

제4장 결과 및 고찰 59
제1절 측정소 측정환경 개선 59
1. large by pass in-line filter를 이용한 펌프 소음 저감 59
2. 전기배선의 개선 62
3. 시료채취관의 이중관 설치 63
4. 폐 가스 처리 환기장치 개발 64
5. 측정소 실내온도 센서 설치 66
6. 화재예방, 실내온도 유지 및 측정환경개선 67
7. 낙뢰 예방 68
8. 디지털 잠금장치를 이용한 측정소 출입 방법의 개선 68
9. 전기절전장치를 이용한 절전방안 69
제2절 측정자료 신뢰성 향상 70
1. 먼지(PM10, PM2.5) 측정자료의 신뢰성 제고 70
2. 오존측정기기의 측정자료 신뢰성 제고 73
3. 표준시간 도입 73

제3절 원격관리시스템 구축 전 문제점 및 해결 방안 74
1. 혼합표준가스 공급 및 연결관 개선 74
가. 교정용 혼합표준가스통 메인 밸브 개선 74
나. 교정장치 가스 연결관 개선 76
2. air compressor 응축수의 원격 배출 장치 개발 78
3. 총탄화수소 측정기 응축수의 원격 배출 장치 개발 86
4. data logger reset module 개발 89

제4절 원격관리시스템 구축 92
1. 원격전원관리시스템 94
가. 전원장치 현재상태 보기 95
나. 전원장치 전원 On / Off 실행방법 95
다. 원격전원제어시스템 구축 97
라. 실내 환기 장치 활용 99
마. high volume air sampler 활용 99
2. 원격교정시스템 100
가. 제작사별 교정방법 100
1) TEI 대기측정장비 운영방법 100
2) Horiba 대기측정장비 운영방법 103
3) T-API 대기측정장비 운영방법 105
나. 통합형 원격 교정 명령어 개발 106
다. 원격 교정 방법 109
3. 원격측정기기모니터링시스템 118
가. 아황산가스(SO2) 측정기 119
나. 이산화질소(NO2) 측정기 122
다. 오존(O3) 측정기 124
라. 일산화탄소(CO) 측정기 126
마. 총탄화수소(THC) 측정기 128
바. 먼지(PM10, PM2.5) 측정기 130
4. 원격관리시스템 구축 133

제5장 결 론 135

References 137
Degree
Doctor
Publisher
조선대학교 대학원
Citation
서광엽. (2009). 대기오염측정망 원격관리시스템 구축에 관한 연구.
Type
Dissertation
URI
https://oak.chosun.ac.kr/handle/2020.oak/8257
http://chosun.dcollection.net/common/orgView/200000238346
Appears in Collections:
General Graduate School > 4. Theses(Ph.D)
Authorize & License
  • AuthorizeOpen
  • Embargo2009-08-04
Files in This Item:

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.