Current process for treating plating waste water has disadvantage of complex steps which may cause economic and occupational hazard problems.
The objects of this study is to develop the removal of heavy metals in plating wastewater by using Alum and FeCl3.
The optimum conditions which used Alum appeared region of pH 8.0, 500㎎/ℓdosage of alkalinity, 440㎎/ℓdosage of coagulant and 9.0㎎/ℓdosage of electrolyte.
And the optimum conditions using FeCl3 was range of pH 8.0, 400㎎/ℓdosage of alkalinity, 500㎎/ℓdosage of coagulant and 8㎎/ℓ of electrolyte.
The removal rate of Cr in the supernatant which produced primary coagulation reached 96.9% by using of Alum, but 95.7% by using of FeCl3.
Alternative Author(s)
Jung Yun - Seong
Affiliation
조선대학교
Department
일반대학원 환경생명공학과
Awarded Date
2008-02
Table Of Contents
List of Tables ⅳ
List of Figures ⅵ
Abstract ⅶ

I. 서론 1

II. 이론적 고찰 3
A. 도금폐수의 특성 및 처리방법 3
1. 성상 및 처리방법 3
2. Ni-Cr 도금공정 및 폐수발생원 6
3. 폐수처리 현황 8
B. 응집 처리 10
1. 응집 이론 10
2. 응집에 미치는 물리․화학적 영향인자 13
3. 알루미늄과 pH의 관계 14
C. 폐수중의 중금속 제거 17
1. 중금속의 특징 17
2. 중금속의 유해성 17
3. 중금속 제거 18

III. 실험재료 및 방법 23
A. 실험재료 23
B. 실험방법 23
1. pH에 따른 영향 23
2. 알칼리제 및 응집보조제의 영향 23
3. 응집제의 영향 23
4. 고분자응집제의 영향 24
C. 분석항목 및 방법 24

IV. 결과 및 고찰 25
A. 도금폐수의 수질 특성 25
B. 화학적 처리 26
1. 황산알루미늄을 사용한 화학적 처리 26
2. 염화제이철(FeCl3)을 사용한 화학적 처리 37
3. 응집제에 따른 응집효율 비교 46

V. 결 론 47

참고문헌 48
Degree
Master
Publisher
조선대학교
Citation
정연성. (2007). 도금폐수의 중금속 처리에 관한 연구.
Type
Dissertation
URI
https://oak.chosun.ac.kr/handle/2020.oak/7067
http://chosun.dcollection.net/common/orgView/200000236039
Appears in Collections:
General Graduate School > 3. Theses(Master)
Authorize & License
  • AuthorizeOpen
  • Embargo2008-02-19
Files in This Item:

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.