- A jet pump is a fluid carrying device which spouts fluid of high pressure from a driving engine pipe and absorbs fluid of high pressure whose pressure is increased through exchange of momentum with surrounding gas of low pressure.
It is applied for various types of industries such as heat engines, water power and thermal power plants, ducts for air conditioning, chemical and petroleum chemistry, food and environment industry in that it provides smooth operation in absorbing solid as well as fluid and gas.
Vapor-vapor jet pump are widely used for absorption, mixing and dehydration in industrial fields and fluid-gas jet pumps have been considered most important for air conditioners to control a variety of harmful gases and to create pleasant environment of structures.
Jet pumps can be easily constructed and installed irregardless of size of systems, can be easily used at the places involved in fluid and have little need of maintenance, and its expense is reasonable.
This study is to identify floating characteristics of jet pumps, mean velocity, distribution of total pressure through CFD analysis. For the purpose, it changed the ends of driving duct with diameter ratio of 1 : 3.21, 1 : 2.25, and 1 : 1.86, found optimal points of driving engine ducts in each diameter ratio and conducted the analysis through PIV experiment. The results are presented as follows:
(1). When the ends of each driving duct with diameter ratios of 1:3.21, 1:2.25 and 1:1.86 were placed in 1.333, 1.213 and 1.133, the largest effect of absorption was found, but the effect was not related to velocity change.
(2). For velocity distribution of the main duct when driving duct were placed at optimal points according to diameter ratios, more than 33% the velocity at the wall increased
(3). This study analysed PIV at optimal points according to diameter ratios of jet pumps and found that CFD flowing is consistent with PIV flowing. As the diameter of driving duct increased, a large eddy flow occurred, which caused decreased efficiency. It was found that the efficiency decreased as the size of driving duct increased in the results of CFD. Through this result, we found that the results of CFD were consistent with those of actual PIV test. (4). For increased efficiency of flow quantity of jet pumps, we have to find optimal points of driving duct at each diameter ratio. Atoptimal points, flow quantity efficiency as well as absorption effect was the highest.
(5). When the end of driving duct was located in the center of the absorption duct, average 11% of efficiency decreased compared to the case that it was placed at the optimal point. When it was extended over optimal point, mean 23% of efficiency deceased. As the driving duct was longer, flow quantity efficiency was lower, and when the end of driving duct was placed at optimal point, flow quantity efficiency was the best.
(6) When a diameter condition of driving duct was 1 : 3.21, the efficiency was the best, and as inlet velocity was faster, the efficiency increased. The flow quantity efficiency of 1 : 3.21 was 32% higher than that of 1 : 2.25, and the flow uantity efficiency of 1 : 3.21 was 46% higher than that of. As the ratio of the expanded duct to driving duct increased, the efficiency decreased.
- Alternative Title
- A Study on the Flow Characteristics of Driven Duct of Position Change of Jet Pump
- Alternative Author(s)
- Jang, Hyun-Jun
- Affiliation
- 조선대학교 대학원
- Department
- 일반대학원 기계공학과
- Advisor
- 이행남
- Awarded Date
- 2007-08
- Table Of Contents
- 第 1 章 序論 = 1
第1節 연구 배경 = 1
第2節 연구의 목적 = 3
第 2 章 理論的 背景 = 5
第1節 Jet pump의 이론식 = 5
1. Jet pump내의 유동 지배방정식 = 5
第2節 CFD 이론적 배경 및 이론식 = 8
1. CFD 이론적 배경 = 8
2. 유한체적법(FVM) = 9
第3節 PIV 실험의 이론적 배경 및 이론식 = 18
1. PIV의 개요 = 18
2.PIV 시스템의 구성 = 20
3.영상처리 = 22
3 章 數値解析 및 實驗 = 27
第1節 실험장치 = 27
第2節 CFD 수치해석 = 29
第3節 PIV 계측실험 = 32
第 4 章 結果 및 考察 = 36
第1節 CFD 결과 및 고찰 = 36
1. 속도 분포 = 37
2. 전압력 분포 = 49
第2節 속도 및 압력분포 특성 분석 = 60
第3節 PIV 결과 및 고찰 = 75
第4節 유량효율 = 82
第 5 章 結論 = 84
REFERENCE = 85
- Degree
- Master
- Publisher
- 조선대학교 대학원
- Citation
- 장현준. (2007). 분사펌프의 구동관로의 위치변화에 따른 유동특성 연구.
- Type
- Dissertation
- URI
- https://oak.chosun.ac.kr/handle/2020.oak/6875
http://chosun.dcollection.net/common/orgView/200000234383
-
Appears in Collections:
- General Graduate School > 3. Theses(Master)
- Authorize & License
-
- AuthorizeOpen
- Embargo2007-11-13
- Files in This Item:
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.