CHOSUN

다이아몬드 기구로 삭제한 와동에서 2단계 접착제의 미세누출 비교

Metadata Downloads
Author(s)
이명구
Issued Date
2006
Abstract
The purpose of this study was to compare the marginal microleakage of different 2-step adhesive systems in Class V cavities prepared with different diamond points.
Forty Class V cavities were prepared with two different (coarse or fine) diamond points on cervical third of extracted molars. The occlusal and gingival margin of cavities was located in enamel and dentin, respectively. They were divided into one of four equal groups (n=10) and ; Group 1-prepared with coarse diamond point (EX-41) and restored with Single Bond and Z 250, Group 2-prepared with fine diamond piont (TF-21F), and restored with Single Bond and Z 250, Group 3-prepared with coarse diamond point (EX-41) and restored with Clearfil SE Bond and Clearfil AP-X, Group 4-prepared with fine diamond point (TF-21F) and restored with Clearfil SE Bond and Clearfil AP-X.
Specimens were thermocycled, immersed in a 2% methylene blue solution for 24 hours, and bisected longitudinally. They were observed leakages at enamel and dentinal margins. Data were analyzed using Mann-Whitney and Wilcoxon signed ranked test.
The results of this study were as follows;
1. At both enamel and dentinal margin, microleakage of group 3 was statistically higher than those of group 1, 2 and 4 (p < 0.01).
2. There were not statistically different among the microleakage of group 1, 2 and 4 at both enamel and dentinal margin (p < 0.01).
3. Enamel microleakage was statistically higher than dentinal microleakage in all groups (p <0.05).
In conclusion, marginal microleakage of Single Bond was not affected by type of diamond points. But Clearfil SE Bond showed higher marginal microleakage at both enamel and dentinal margin when Class V cavity was prepared with coarse diamond point.
Alternative Title
Microleakage of 2-step adhesive systems in diamond-prepared cavity
Alternative Author(s)
Lee, Myung-Goo
Affiliation
조선대학교 대학원
Department
일반대학원 치의학과
Advisor
민정범
Awarded Date
2007-02
Table Of Contents
영문초록 = ⅲ
Ⅰ. 서론 = 1
Ⅱ. 실험재료 및 방법 = 3
Ⅲ. 실험결과 = 7
Ⅳ. 총괄 및 고찰 = 9
Ⅴ. 결론 = 12
참고문헌 = 13
Degree
Master
Publisher
조선대학교 대학원
Citation
이명구. (2006). 다이아몬드 기구로 삭제한 와동에서 2단계 접착제의 미세누출 비교.
Type
Dissertation
URI
https://oak.chosun.ac.kr/handle/2020.oak/6580
http://chosun.dcollection.net/common/orgView/200000233985
Appears in Collections:
General Graduate School > 3. Theses(Master)
Authorize & License
  • AuthorizeOpen
  • Embargo2008-09-01
Files in This Item:

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.