- Air fluid analysis with Integrated Blower BLDC structural improvements. Integrated Blower BLDC structure is used for water removal, such as a blowing device, hand dryer, dryer, dehumidifier, car washing machine. The purpose is to remove rainwater and moisture from the umbrella at high pressure and high speed for a short time using the water separator principle. The authors conducted the 1st, 2nd, and 3rd design and experiments to achieve the optimal integrated Blower BLDC structure. In addition, the research paper was verified through simulation, experiments, and prototypes to analyze the wind speed, dehydration rate, and Air Fluid for the structure.