CHOSUN

티타늄 전극과 전기분해를 이용한 상수 원수의 망간 제거

Metadata Downloads
Author(s)
최영균 서호영 김성홍
Issued Date
2020
Keyword
Manganese removal Electrolysis Titanium electrode Manganese dioxide coated titanium electrode
Abstract
Manganese causes the black water of tap water. In this study, we investigated the effect of electrolysis for the removal of manganese under various conditions of electrode type, contact time, operating voltage, and catalyst use. The following results were obtained. The manganese removal rate is proportional to the contact time. The difference of manganese removal rate between the titanium electrode and the manganese dioxide coated electrode was not significant. The manganese removal rate was increased as the voltage increase up to 24V. However, it was slightly decreased at 30V. Manganese removal was not increased by electrolysis combined by aeration but the rate was rapidly increased by electrolysis combined with hydrogen peroxide.
Authorize & License
  • AuthorizeOpen
Files in This Item:
  • There are no files associated with this item.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.