플라즈마 전해 산화된 생체용 Ti 합금의 표면특성
- Author(s)
- 김비룡
- Issued Date
- 2018
- Abstract
- In this study, the effects of applied potential on the surface characteristics of plasma electrolytic oxidized (PEO) Ti-6Al-4V alloy for biomaterials were investigated with the applied voltage of 150V, 250V, and 350V in the electrolyte containing Ca and P ions.
PEO film was formed in mixed solution of 0.15 M calcium acetate monohydrate and 0.02 M calcium glycerophosphate electrolyte at 150V ~ 350V for 3 minutes using DC power supply. PEO films formed at various applied voltages were examined surface characteristics by roughness test, scratch test, nanoindentation test, wettability test for biocompatibility, and electrochemical test. Surface morphologies and structures of the PEO-treated alloy were determined by field-emission scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffractometer. The results were as follows;
1. The PEO-treated surface with a porous oxide film containing hydroxyapatite (HA) was formed. The size of pores at 150V was smaller compared to others. For 250V, uniform size of pores and HA formation were observed. At 350V, size of pores increased, the number of pore decreased as compared with the surface formed at 150V and 250V. Even cracks on the surface were observed at 350V.
2. From the result of EDS analysis, PEO-treated surface shows that the Ca / P ratio increased as the applied voltage increased, and the uniform distribution of Ca and P elements was noticed over the entire surface.
3. The anatase, rutile, and HA phase were observed on the PEO-treated surface. As the applied voltage increased, the XRD peaks of anatase phase and the HA phase gradually increased. Rutile was observed only at 350V.
4. As a result of the scratch test the films were broken at the load at 5.3N, 2.3N, and 6N for the PEO surfaces formed at 150V, 250V, and 350V. Also, The peeling of film was observed of the loads of 16.4N, 29.6N, and 8.1N, respectively, for the samples prepared at 150V, 250V, and 350V. The oxide film peeled at the highest load for the sample prepared at an applied voltage of 250V.
5. The nano-indentation analysis shows, the hardness of the samples increased and the elastic modulus decreased with increasing applied voltage.
6. From the results of wettability and surface roughness test on the PEO surface, as the applied voltage increased, the contact angle was decreased and the surface roughness was increased.
7. From the electrochemical corrosion test, the corrosion potential decreased and corrosion current density increased with the applied voltage. The polarization resistance was increased from 150V to 250V, and then decreased at 350V.
In addition, it was noticed that small HA particles on the PEO surface formed at an applied voltage of 350V were disappeared, and that the edges of the pores and cracks were smoothened as a result of attack of chloride ions.
- Alternative Title
- The surface characteristics of plasma electrolytic oxidized Ti alloy for biomaterials
- Alternative Author(s)
- Kim Bi Ryong
- Department
- 일반대학원 첨단부품소재공학과
- Advisor
- 최한철
- Awarded Date
- 2018-08
- Table Of Contents
- 목 차
LIST OF TABLES ......................................................... ⅱ
LIST OF FIGURES ........................................................ ⅲ
ABSTRACT ................................................................ ⅴ
제 1 장 서 론........................................................... 01
제 2 장 실험 방법 ...................................................... 03
제 1절 시료준비 ...................................................... 03
제 2절 플라즈마 전해 산화 (PEO) 처리 ............................. 03
제 3절 PEO 처리 표면 및 결정구조 조사.................................. 05
제 4절 PEO 처리 표면의 거칠기 시험 .................................... 06
제 5절 PEO 처리 표면의 탄성계수 측정 .................................. 06
제 6절 PEO 처리 표면의 접착력 시험 .................................... 06
제 7절 PEO 처리 표면의 젖음성 시험 .................................... 06
제 8절 PEO 전기화학적 특성시험 ........................................ 07
제 3 장 연구 결과 및 고찰............................................... 09
제 1절 PEO 처리 표면 관찰 ........................................... 09
제 2절 PEO 처리 표면의 결정구조 .................................. 14
제 3절 PEO 처리 표면코팅의 접착력 ..................................... 16
제 4절 PEO 처리 표면의 탄성계수와 경도 ............................... 18
제 5절 PEO 처리 표면의 젖음성 ......................................... 21
제 6절 PEO 처리 표면의 전기화학적 특성 ................................ 25
제 4 장 결 론 .......................................................... 35
참고문헌 ................................................................ 37
- Degree
- Doctor
- Publisher
- 조선대학교 대학원
- Citation
- 김비룡. (2018). 플라즈마 전해 산화된 생체용 Ti 합금의 표면특성.
- Type
- Dissertation
- URI
- https://oak.chosun.ac.kr/handle/2020.oak/13684
http://chosun.dcollection.net/common/orgView/200000267015
-
Appears in Collections:
- General Graduate School > 4. Theses(Ph.D)
- Authorize & License
-
- AuthorizeOpen
- Embargo2018-08-24
- Files in This Item:
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.