CHOSUN

캐드캠으로 제작된 임플란트 맞춤형 지대주의 임상적 평가

Metadata Downloads
Author(s)
윤태경
Issued Date
2016
Keyword
CAD/CAM abutment, implant, splinting, bone loss, prosthesis evaluation
Abstract
Purpose

Customized abutments made by CAD/CAM method are widely used in implant dentistry. However, there is not sufficient data about long-term follow-up in patients with implant prosthesis using CAD/CAM abutment. In this study, the retrospective study is executed in patients using customized abutment for 4 years of follow-up

Materials and methods

A. Materials
1. Patient assessment
129 patients had treatment of fixed implant prosthesis with CAD/CAM customized abutment at Chosun University Dental Hospital. The follow-up for 19 patients among 129 patients was not accomplished, so 110 patients had gone through 4 years of follow-ups.

2. Implant evluation
271 implants of five brands (Astra, Biomet 3i, Zimmer, Dentis, Osstem) were evaluated according to splinting and location of implant fixture.
B. Methods
Patients were examined periodically at 3, 6 months, 1, 2, 3, 4 years after the final placement of the implant. Radiological evaluation for bone loss according to splinting and location of implant fixture and clinical evaluation (abutment fracture, screw loosening, screw fracture, porcelain veneer fracture, retention loss of prosthesis, contact point loosening, implant failure) according to splinting and location ofimplant fixture were performed.

C. Statistic Analysis
Statistical analysis was performed with SPSS Ver. 22. 0

Results

A. Radiographic evaluation
1. The amount of bone loss according to splinting
The mean cumulative bone loss in the non-splinting implant group was 0.27 mm, in the splinting implant group was 0.50 mm. There was no statistically significant difference between the groups.
2. The amount of bone loss according to location of implant fixture
The mean cumulative bone loss in the maxillary anterior part was 1.37 mm, maxillary posterior part was 0.39 mm, mandibular anterior part was 0 mm, mandibular posterior part was 0.30mm. There was statistically significant difference.

B. Clinical evaluation
1. The clinical prosthesis evaluation according to splinting
Prosthesis evaluation analyzed by chi-square test. With this result, statistically significant difference was observed in screw loosening.
2. The prosthesis evaluation according to location of implant fixture
Prosthesis evaluation analyzed by chi-square test. With this result, statistically significant difference was observed in porcelain veneer fracture and retention loss of prosthesis.
Conclusion

① The amount of bone loss was greater in the splinting group than the non-splinting group
② The amount of bone loss was greater in the maxillary anterior part than another group
③ Screw loosening was less in the splinting group than the non-splinting group
④ Prosthesis deformation and retention loss of prosthesis were greater in the maxillary anterior part than other group
Alternative Title
Clinical Evaluation of Computer Aided Design/Computer Aided Manufacturing (CAD/CAM) Customized Abutment of Implant
Alternative Author(s)
Yun, Tae-Gyeong
Affiliation
조선대학교 치의학전문대학원
Department
일반대학원 치의학과
Advisor
김희중
Awarded Date
2017-02
Table Of Contents
표 목 차 ······································································· ⅱ

도 목 차 ········································································· ⅲ


영문초록 ········································································ ⅳ

Ⅰ. 서 론 ········································································ 1

Ⅱ. 연구 대상 및 방법 ··························································· 2

Ⅲ. 연구 결과 ···································································· 6

Ⅳ. 총괄 및 고찰 ······························································· 10

Ⅴ. 결 론 ······································································· 12

참고문헌 ········································································· 13
Degree
Master
Publisher
조선대학교 치의학전문대학원
Citation
윤태경. (2016). 캐드캠으로 제작된 임플란트 맞춤형 지대주의 임상적 평가.
Type
Dissertation
URI
https://oak.chosun.ac.kr/handle/2020.oak/13197
http://chosun.dcollection.net/common/orgView/200000266190
Appears in Collections:
General Graduate School > 3. Theses(Master)
Authorize & License
  • AuthorizeOpen
  • Embargo2017-02-21
Files in This Item:

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.