CHOSUN

전자선량계를 이용한 핵의학 방사선작업종사자의 피폭선량평가

Metadata Downloads
Author(s)
송하진
Issued Date
2016
Keyword
Dose of the lens, Radiation workers, I-123, Tc-99m, FDG
Abstract
It is suggested that the dose limit recommended in the Enforcement Decree of Korea's Nuclear Safety Act should not exceed 150 mSv per year for radiation workers. Recently, however, ICRP 118 report has suggested that the threshold dose of the lens should be reduced to 0.5 Gy and the mean dose should not exceed 50 mSv per year for an average of 20 mSv over 5 years. Based on these contents, I-123, Tc-99m, and FDG, which are radioisotope drugs that are used directly by radiation workers in the nuclear medicine department in Korea are expected to receive a large dose of radiation in the lens in distribution and injection jobs to administer them to patients. Since it was suggested that the dose equivalent of the lens presented in ICRP 103 can be measured by using dose equivalent of skin for the monitoring purpose, this study measured the lens exposure dose of the radiation workers in the nuclear medicine department by using ED3 Active Extremity Dosimeter, an extremity dosimeter. The measured values were analyzed by the work of the radiation workers in the nuclear medicine department, the presence or absence of shielding, and the source. In addition, by checking the work, presence or absence of shielding of each source, we performed descriptive statistics by using the SPSS Version 21.0 for the exposure dose given to the lens per 1 mCi. As a result of measuring distribution and injection tasks for each worker, the annual dose is relatively low, but it is difficult to determine the exact dose because it is limited to distribution and injection tasks. However, by using the Dose Calibrator by using the result of analyzing the exposure dose per 1 mCi, it is expected that the radiation workers in the nuclear medicine department themselves can judge the expected exposure dose to the lens. In addition, since continuous exposure may cause lens opacity and cataract, it is thought that radiation safety managers and related regulatory agencies should manage and continually study the exposure dose of the lens.
Alternative Title
Dose evaluation of nuclear medicine radiation workers usin electronic dosimeter
Alternative Author(s)
Song, Ha Jin
Affiliation
조선대학교 대학원
Department
일반대학원 원자력공학과
Advisor
정운관
Awarded Date
2017-02
Table Of Contents
List of Figures
List of Tables
ABSTRACT
제1장. 서론
제1절. 연구 배경
제2절. 연구 목적
제2장. 본론
제1절. 이론적 배경
1. 방사선
2. 방사선량
제3장. 연구재료 및 방법
제1절. 연구재료
제2절. 측정장비 및 측정방법
1. ED3(Active Extremity Dosimeter)
2. 측정방법
제3절. 통계분석방법
제4장. 결과
제1절. 종사자 수정체 피폭선량 평가
1. 연간 수정체 예상 피폭선량
2. 차폐여부에 따른 피폭선량 비교
3. 분배 및 주사에 따른 피폭선량 비교
4. 분배 업무할 때 차폐여부에 따른 피폭선량 비교
5. 주사 업무할 때 차폐여부에 따른 피폭선량 비교
제2절. 선원별 피폭선량 평가
1. 선원별 피폭선량 평가
2. 각 선원별 1mCi 환산
제5장. 결론
참고문헌
Degree
Master
Publisher
조선대학교 대학원
Citation
송하진. (2016). 전자선량계를 이용한 핵의학 방사선작업종사자의 피폭선량평가.
Type
Dissertation
URI
https://oak.chosun.ac.kr/handle/2020.oak/13181
http://chosun.dcollection.net/common/orgView/200000266145
Appears in Collections:
General Graduate School > 3. Theses(Master)
Authorize & License
  • AuthorizeOpen
  • Embargo2017-02-21
Files in This Item:

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.