Purpose : The purpose of this study is to compare the accuracy of the CT guided implant template (implant template) that was produced by using an oral scanner according to the edentulous distance.

Materials and methods : Five acrylic resin mandibles with teeth #15, #16, #17, #25, #26, #27 as missing were made using radiopaque resin. The mandibles were then scanned with CBCT and oral scanner. Six implants were planned for the treatment of the edentulous site using a 3D software program. The implants were inserted on the cast according to the CAD/CAM-fabricated implant template (In2Guide, Cybermed, CA, USA) and then were rescanned with CBCT. Presurgical and postsurgical CBCT Scans were superimposed to compare the virtual implant placement with the actual implant placement. The virtually planned and actually placed implant positions were compared for the apex, platform, and angle. SPSS Ver.19.0. was used for Kruskall-Wallis test and Mann-Whitney test (P<.05).

Results : The mean angular deviation of the long axis of second premolar, first molar, second molar was 0.450±0.14°, 0.510±0.15° and 0.540±0.19°, respectively. The distance between the planned and placed implants was 0.230±0.06 mm, 0.270±0.09 mm, 0.480±0.12 mm at the platform and 0.390±0.06 mm, 0.430±0.06 mm, 0.640±0.07 mm at the apex, respectively.

Conclusion : There was no significant difference in the angular deviation of the long axis for each implant site. However, the distance between the planned and placed implants at the neck and apex showed less accuracy at the implant site of second molar.
Alternative Title
Accuracy of the CT guided implant template by using an intraoral scanner according to the edentulous distance
Alternative Author(s)
Kang, Byeong gil
Affiliation
조선대학교 치과병원 치과보철과
Department
일반대학원 치의학과
Advisor
정재헌
Awarded Date
2016-02
Table Of Contents
Ⅰ. 서 론 1
Ⅱ. 연구 재료 및 방법 3
A. 연구 재료
1. 임플란트 식립 모형 제작 및 임플란트 선택 3
B. 연구 방법
1. Implant surgical template 제작 4
2. 임플란트 식립 5
3. Implant surgical template의 정확도 비교 7
C. 통계학적 분석 7
Ⅲ. 연구 결과 9
A. Variation of platform of implant 9
B. Variation of apex of implant 10
C. Variation of angulation of implant 11
Ⅳ. 총괄 및 고찰 12
Ⅴ. 결 론 15
참고문헌 16
Degree
Master
Publisher
조선대학교 대학원
Citation
강병길. (2016). 구강스캐너를 이용한 CT guided implant template의 무치악 거리에 따른 정확도 분석.
Type
Dissertation
URI
https://oak.chosun.ac.kr/handle/2020.oak/12647
http://chosun.dcollection.net/common/orgView/200000265261
Appears in Collections:
General Graduate School > 3. Theses(Master)
Authorize & License
  • AuthorizeOpen
  • Embargo2016-02-25
Files in This Item:

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.